A performance simulation estimates how much energy a design will produce in a typical year. Run one after you change a design, so its production and savings figures stay current. This article covers running a simulation in Design Mode and Sales Mode, changing a design's simulation settings, and reading the results.
In this article:
- Before you begin
- Running a simulation in Design Mode
- Changing a design's simulation settings
- Viewing results and simulation logs
- Recalculating in Sales Mode
- When a financier sets your simulation settings
- FAQ
- Related articles
Before you begin
- Place panels on the design. To use the Aurora simulation engine, connect every panel to an inverter. See Stringing and Connecting.
- Enter the customer's energy usage. Without it, the production estimate still runs, but calculations that depend on usage, such as storage, avoided cost, and financing, fail and show errors. See Entering a customer's energy usage.
- Use Design Mode to change a design's simulation settings. Sales reps can't change simulation settings in Sales Mode.
Running a simulation in Design Mode
These steps start from an open design in Design Mode and end with updated results in the summary bar.
- Click Simulate system in the toolbar.
- Wait for the simulation to finish. While it runs, messages at the bottom of the screen show progress, such as "4 simulations running" and "Performance simulation completed." Finished items collapse into a summary, such as "4 completed," which you can close with Dismiss.
- Check for warnings and errors. Warnings start with "Performance simulation warning:" and errors start with "Performance simulation failed:". See Troubleshooting performance simulation warnings and errors.
When the simulation finishes, the button changes to Simulation updated, and the summary bar shows the new results. If the simulation fails, or a storage, avoided cost, or financing calculation fails, the button stays on Simulate system. A failed simulation shows dashes in the summary bar instead of results, even if "Performance simulation completed" also appeared.
After you change the design, its simulation settings, the energy usage, or the utility rates, the button switches back to Simulate system. Until you run the simulation again, results in the summary bar may be missing or out of date.
Changing a design's simulation settings
Each design has its own simulation settings, which start from your account's defaults. Changing those defaults later doesn't update existing designs.
- Click Settings (the gear icon) in the Design Mode toolbar.
- Click the Simulation tab.
- Change the settings you need. Changes take effect as soon as you make them, so you don't need to save.
- Click Simulate system to update the results.
The Simulation tab has four sections:
| Section | What it includes | Learn more |
|---|---|---|
| Simulation | Simulation engine (Auto, Aurora, or PVWatts v6), Shading engine, Use horizon shading, Use LIDAR shading, and Use module's light-induced degradation and annual degradation data, if available | Aurora simulation engine, LIDAR Shading |
| Aurora | Weather dataset, Weather station, Irradiance model, Inverter clipping, and Submodule simulation | Aurora simulation engine, Weather datasets |
| PVWatts | Weather dataset, Inverter efficiency, and DC-to-AC ratio | PVWatts simulation engine |
| System losses (annual) | Loss percentages, such as Soiling and Snow, and the Estimated total loss | System losses |
With Simulation engine set to Auto, Aurora uses the Aurora engine when every panel is connected to an inverter. If any panel isn't connected, it simulates the whole design with PVWatts. To change the defaults for new designs, see Performance simulation settings – Account configuration.
Viewing results and simulation logs
The summary bar at the top right shows Production and, depending on your account and project, Usage, Self-sufficiency, and Bill savings, along with the system size. If the project has energy usage, Production shows the offset — annual production as a percentage of annual usage. Otherwise, it shows annual production in kWh.
For more detail, open the Production panel:
- Click Production in the summary bar.
- Click Advanced, then System losses, to see where energy is lost. This diagram is available after an Aurora engine simulation. See System loss diagram.
- Click Simulation logs under Advanced to see the settings and assumptions the simulation used.
The Production panel shows:
- Annual, Average month, and Offset — annual production, the monthly average, and the offset.
- Monthly production (kWh) — a chart that compares Energy usage with New system production for each month. To copy the monthly values as a table, click the icon at the top right of the chart.
- PV system — Panels, System yield (annual production per kWp of system size), and Performance ratio (annual production divided by the After PV Conversion value in the system loss diagram). PVWatts simulations don't calculate a performance ratio, so it shows 0.00.
- LIDAR shading is enabled — hover over the info icon next to it for a link to the setting.
- Energy usage — the project's Annual energy and the Edit energy profile button. See Entering a customer's energy usage.
To download hourly production values, see Downloading hourly production data.
Recalculating in Sales Mode
In Sales Mode, results update only when you recalculate, and the simulation uses the design's settings from Design Mode. These steps start after you change a design in Sales Mode.
- Click Recalculate at the top right of the map. Until you recalculate, the energy offset percentage at the top right shows 0% or is greyed out.
- Wait for the messages at the bottom of the screen to finish, such as "Calculating your system and updating eligible incentives."
- Click the energy offset percentage at the top right to open the System summary.
The System summary shows Energy offset (with Annual production and Annual usage), Self-sufficiency, Bill offset, and System size, depending on your account and project.
If your account adds inverters automatically in Sales Mode, Recalculate also adds inverters and strings the panels. See Inverters and Optimizers in Sales Mode. If stringing fails, an error such as "AutoStringer: Request validation failed: Error: Incompatible Components" appears. Aurora then removes the design's strings and inverters, including ones added in Design Mode, and simulates the design with PVWatts. To fix it, connect the panels to inverters in Design Mode, then click Simulate system. If you can only use Sales Mode, see How to contact Aurora support.
When a financier sets your simulation settings
When a design uses an integrated third-party ownership (TPO) financing option, the financier's requirements set all of the design's simulation settings, including system losses. This applies in both Design Mode and Sales Mode.
On the Simulation tab, the settings appear as read-only values instead of dropdowns and toggles, except Use LIDAR shading. No message appears to explain the change.
If you switch to a financing option that isn't TPO, the settings return to the values the design had before you selected the TPO financing.
FAQ
Why did my production change when I clicked Simulate system?
The previous results were from the last simulation, before your latest changes to the design, settings, energy usage, or utility rates. The new results include those changes.
Why do I see errors about storage, avoided cost, or financing?
These calculations need the customer's energy usage and a successful performance simulation. Enter usage for the project, fix any simulation error, then click Simulate system again.
Why can't I change the simulation settings on a design?
A financier may set them. See When a financier sets your simulation settings. Sales reps also can't change simulation settings in Sales Mode.