When a performance simulation can't run as set up, Aurora shows a warning or an error at the bottom of the screen. This article explains the most common messages, why they appear, and how to fix them.
In this article:
Problem
You see one of these messages after you click Simulate system in Design Mode or Recalculate in Sales Mode:
- Performance simulation failed: There are panels that are not connected to inverters. Please ensure all panels are connected to inverters before running an Aurora simulation.
- A warning that starts with Performance simulation warning: Simulated system using PVWatts because modules are not connected to inverters.
- A warning that includes PVWatts inverter efficiency must be between 90% and 99.5%
- Avoided cost calculation timed out or Financing calculation timed out
- AutoStringer: Request validation failed: Error: Incompatible Components in Sales Mode
After a failed simulation, the summary bar shows dashes instead of results, even if "Performance simulation completed" also appeared.
Cause
- Simulation failed. Simulation engine is set to Aurora, and at least one panel isn't connected to an inverter. The Aurora engine needs every panel connected, so the simulation doesn't run.
- Simulated using PVWatts. Simulation engine is set to Auto, and at least one panel isn't connected to an inverter, so Aurora simulated the whole design with PVWatts. When some panels are connected, the rest of the warning names the inverter efficiency Aurora used for the unconnected panels. It calls this your account setting, but the value comes from Inverter efficiency in the design's PVWatts settings.
- Inverter efficiency out of range. The design's PVWatts Inverter efficiency is outside 90%–99.5%, so Aurora used 96% for the unconnected panels.
- Calculations timed out. Avoided cost and financing calculations need a successful performance simulation and the customer's energy usage. When the simulation fails, they time out.
- AutoStringer error. If your account adds inverters automatically in Sales Mode, Recalculate adds inverters and strings the panels. If it can't, Aurora removes the design's strings and inverters and simulates the design with PVWatts. See Running a performance simulation.
Resolution
If the simulation failed or used PVWatts because panels aren't connected, connect every panel to an inverter. These steps start from the design in Design Mode.
- Click String / connect in the left panel.
- Connect each unconnected panel to an inverter. See Stringing and Connecting.
- Click Simulate system.
If the inverter efficiency is out of range, change the design's PVWatts value. These steps start from the design in Design Mode.
- Click Settings (the gear icon) in the toolbar.
- Click the Simulation tab.
- Enter a value from 90 to 99.5 in Inverter efficiency under PVWatts.
- Click Simulate system.
To change the value that new designs start with, an admin can update Default inverter efficiency in Settings > Performance simulations.
If avoided cost or financing calculations timed out, fix the simulation error first and make sure the project has energy usage, then click Simulate system again.
If you see the AutoStringer error in Sales Mode, connect the panels to inverters in Design Mode, then click Simulate system. If you can only use Sales Mode, contact Aurora Support. For how Sales Mode adds inverters, see Inverters and Optimizers in Sales Mode.
Still having trouble?
Contact Aurora Support and include a link to the design, a screenshot of the message, and whether you were in Design Mode or Sales Mode. See How to contact Aurora support.
FAQ
I missed the error message. How do I see it again?
Click Simulate system again. The "Performance simulation failed" message closes on its own after a few seconds, and Aurora doesn't save it in the simulation log or Notifications. Warnings stay until you close them.
Why does the simulation log say "Proceeding without submodule simulation"?
At least one panel's module doesn't support submodule simulation, so Aurora ran a module-level simulation instead. See Submodule (cell string) simulation.