P50 and P90 describe how likely a system is to produce at least a given amount of energy in a year. They help lenders and investors assess the financial risk that comes from year-to-year changes in weather. This article explains what each value means and which one Aurora uses.
What P50 and P90 mean
| Value | Meaning |
|---|---|
| P50 | The annual production that the system has a 50% chance of reaching or exceeding in a given year. It's the middle of the expected range. |
| P90 | The annual production that the system has a 90% chance of reaching or exceeding. It's lower than P50, which makes it the more conservative estimate for assessing financial risk. |
Calculating these values takes many years of weather data, so that the result reflects how much the weather changes from year to year. For more detail, see NREL's P50/P90 Analysis for Solar Energy Systems Using the System Advisor Model.
How Aurora uses them
Aurora's production estimate is a P50 value. It uses weather data for a typical year at the project's location, so it describes a typical year rather than any specific year. Actual production in a given year can be higher or lower. See Weather datasets.
Aurora doesn't calculate a P90 production estimate. If a lender asks for one, you'll need an analysis outside Aurora that uses many years of weather data. Aurora uses P90 only for battery backup duration. See Backup Duration - Calculations.